BW GasAlertMicroClip X3四合一氣體檢測儀(氧氣5年壽命)大電量長續(xù)航,IP68防水等級 檢測:H2S,CO,O2,可燃?xì)怏wLEL%,可選一、二、三、四種氣體。
加拿大BW四合一氣體檢測儀分為三款,一款為MC2-4經(jīng)典款,價格優(yōu)惠,精巧的機身,使用便捷,廣受廣大用戶歡迎,現(xiàn)生產(chǎn)線設(shè)在上海。作為進(jìn)口的BW四合一氣體檢測儀,分為三款,一款為BW泵吸式四合一氣體檢測儀,一款為續(xù)航型GasAlertMicroClipXL(MCXL-4),一款GasAlertMicroClipX3(MCX3-4)為IP等級更高,使用環(huán)境更為惡劣的地區(qū)。可支持使用氧氣5年壽命的傳感器,可以在中國北方區(qū)域使用。
BW四合一氣體檢測儀首次充電:
XT:2-3 小時
XL-X3:5-6 小時
正常充電:
XT:2-3 小時
XL-X3:5-6 小時
XT:電池的標(biāo)準(zhǔn)使用壽命:10 小時,4小時內(nèi)即可充滿
XL-X3:電池的標(biāo)準(zhǔn)使用壽命:18 小時,6小時內(nèi)即可充滿
BW四合一氣體檢測儀性能參數(shù):
GasAlertMicroClip Specifications
GasAlertMicroClip XL GasAlertMicroClip X3
Size 11.3 x 6.0 x 3.2 cm / 4.4 x 2.4 x 1.2 in.
Weight 190 g / 6.7 oz. 179 g / 6.3 oz.
Temperature -20 to +50°C / -4 to +122°F
Humidity 0% - 95% RH (non-condensing)
Alarms Visual, vibrating, audible (95 dB) • Low, High, TWA, STEL, OL (over limit)
Tests Audible/visual alarms on activation; sensors, battery and
circuitry (continuous)
Typical battery life 18 hours; recharges in less than 6 hours
Note: Approximately 20% capacity loss is normal with lithium polymer batteries after
500 charge cycles. Refer to the Operator’s Manual for additional information.
User options Confidence beep
When calibrating the detector, adhere to the following guidelines:
• Recommended gas mixture:
CO: 100 ppm balance N2
H2S: 25 ppm balance N2
LEL: 50% LEL or 2.5% for NA (2.2% for EU) by vol. methane
balance air
O2: 18% by volume, balance N2.
• To ensure accurate calibration, use a premium-grade calibration gas. Gases approved by the National Institute of Standards and Technology (NIST) improve the accuracy of the calibration.
• Do not use a gas cylinder past its expiration date.
• Calibrate a new sensor before use. Install the sensor, activate the detector, and allow the sensor to stabilize before starting calibration (used sensor: 60 seconds / new sensor: 5 minutes, for X3 O2 stabilization takes 60 minutes.
• Calibrate the sensors at least once every 180 days, depending on use and sensor exposure to poisons and contaminants.
• Calibrate the detector if the gas readings varies during startup.
• Calibrate the sensor before defining the alarm setpoints.8
• Calibrate only in a safe area that is free of hazardous gas in an atmosphere of 20.9% oxygen.
• Do not calibrate the detector during or immediately after charging is complete.
• The oxygen sensor can be automatically calibrated each time upon activation (if this feature is enabled). Activate the detector in a normal (20.9%/20.8% oxygen) atmosphere.
BW四合一氣體檢測儀產(chǎn)品結(jié)構(gòu):
規(guī)格尺寸:
XT:11.25 x 6.00 x 2.89 厘米(4.4 x 2.4 x 1.1 英寸)
XL-X3:11.25 x 6.00 x 3.22 厘米(4.4 x 2.4 x 1.2 英寸)
重量:
XT:170 克(6.0 盎司)
XL:190 克(6.7 盎司)
X3:179 克(6.3 盎司)
工作溫度:-4°F 至 +122°F (-20°C 至 +50°C),
存放溫度:-40°F 至 +122°F (-40°C 至 +50°C)
工作濕度: 0% 至 95% 相對濕度(非冷凝)
報警點:可隨地區(qū)變化并由用戶定義。啟動自檢時,所有報警設(shè)置點自動顯示。
檢測范圍:
硫化氫 (H2S):0-100 ppm (增量為 1/0.1 ppm)
CO:0 - 500 ppm (增量為 1 ppm)
O2:0 - 30.0% vol. (增量為 0.1% vol.)
可燃物氣體 (LEL):0 - 100% (LEL 增量為 1%)或0 - 5.0% v/v 甲烷
傳感器類型:
H2S、CO、O2:單一插入式電化電池
可燃?xì)怏w:插入式催化珠
O2 測量原理:毛細(xì)管控制的濃度傳感器或氧氣泵。
報警狀態(tài):TWA 報警、STEL 報警、低限 (OL) 報警、高限報警、多種氣體報警、超限報警、電量不足報警、置信蜂鳴音、
自動關(guān)閉報警。
聲音報警:30 厘米(1 英尺)距離,約 95 分貝(通常為100 分貝)可變脈沖報警器
視覺報警:紅色發(fā)光兩極管 (LED)
顯示屏:字母數(shù)字式液晶顯示屏 (LCD)
背景光:按下按鈕以及在報警條件下亮起 5 秒鐘,除非啟用了隱藏模式。
自檢:啟動時開始進(jìn)行
校準(zhǔn):自動歸零和自動校準(zhǔn)
氧氣傳感器:啟動時進(jìn)行自動校準(zhǔn)(啟用/ 禁用)
用戶現(xiàn)場選項:啟動信息、置信蜂鳴音、鎖定報警、啟用/ 禁用,安全顯示模式、氧氣測量、可燃?xì)怏w傳感器測量、禁用傳感器、設(shè)定校準(zhǔn)間隔、強制校準(zhǔn)、校準(zhǔn)鎖、設(shè)定沖擊間隔、沖擊到期鎖、隱藏模式、語言選擇、啟用/ 禁用自動氧氣校準(zhǔn)、啟動時啟用/ 禁用自動歸零、設(shè)定報警設(shè)置點、設(shè)定量程濃度值、設(shè)定STEL 計算周期、低限報警確認(rèn)、IntelliFlash、置信蜂鳴音與IntelliFlash 間隔。